Over the past decade, water quality issue has caused a series of problems such as the corrosion on boiler, tube burst, turbine salt accumulation and generator corrosion and sediment. Four kinds of tube burst are listed here: First, condenser leaking will cause boiler erosion and tube burst; Second, inappropriate installation will result in bad water quality and tube burst; Third, drawbacks of steam separator on boiler drum will arouse the salt accumulation on super-heater and eventually cause tube burst; Fourth, improper pickling will cause the tube burst of the super-heater and inappropriate equipment lay-up protection will cause the erosion of tubes. Focusing on the problems mentioned above, our engineer team have put forward corresponding solutions such as the new monitor standard on water quality in cooling water system in the generator, effective measures on preventing corrosion and sediment and some cleaning programs. All the proposals supply valuable reference in engineering and they are practical in technical guidance.
Please Ask Questions From Engineers( You may ask questions in Bahasa Indonesia.)
Hot Topic
/ 2017-12-19
Boiler feed water pum0
Why boiler feed water pump side outboard high temperature?
It is common for the pump body to overheat the pump body because of the friction caused by the bearing damage, or because of the lack of oil and oil in the lubricating system. Therefore, after finding that the pump body is overheating, check whether the lubricating system is lacking in oil or lubricating oil containing impurities, and then check whether the bearing is damaged. It is necessary to check whether the rolling bearing or bracket cover is too small for the overheating of the newly overhauled pump body. Pump body after pass the inspection still fever should check whether the pump shaft is bent or two different axis center, at the same time to check the impeller balance, adjustment pump shaft or two shaft concentricity, remove the impeller balance hole, to ensure the pump shaft and the impeller rotation balance, troubleshooting.
/ 2017-11-17
Electrical
See the bottom pic!! My plant capacity is 15 MW and I have maintaining always negative reactive power.Is there any problem if I maintain negative reactive power always???
Hello, sir. Negative reactive power can not allow to run in the longer time. Please adjust power factor, control it to around 80. If still have questions, please leave your name with email address and mobile number. I will contact you right away, and if needed, send our technician to help solve your problems.
/ 2016-10-05
Describe the procedure of scraping the steel pad of bush?
In the bush depression nest coat with a thin layer of red lead, under the three steel pad thereon grinding coloring the colored marks be repaired using a fine rasp or scraper blade, after three steel pad contacts simultaneously qualified, and then make the pad on the lower part steel pad thickness reduce 0.05 ~ 0.07mm, it can achieve scraping requirements. Note that identify colored marks, smear red lead oil too much is likely to cause the illusion.