Phenomenon:
--- Bed temperature indication is high or low.
--- High bed temperature alarming.
--- The load increases or decreases.
Reasons:
--- The feeding particle size is too large or too small.
--- Measuring fault of bed temperature thermocouple.
--- The feeder works abnormally.
--- Ratio of the primary air and the secondary air is imbalance.
--- Fault of slag-discharging system.
--- The limestone system can not operate properly.
Treatment:
--- Check the bed temperature thermocouple.
--- Check whether the operation and the controlling of the coal feeder are normal or not.
--- Make the air distribution to be reasonable, and adjust the ratio between the primary air and the secondary air.
--- If the combustion is not stabilized because of the low bed temperature, oil gun should be adopted as the combustion-supporting.