Home > Operational Area > BOILER
The Factors Influencing Fluidized Bed Boiler Load

Coal quality, bed temperature, bed pressure, oxygen content and the ratio of the primary and secondary air , water supply temperature, the purity of the heating surface at the rear. During the circulating fluidized bed boiler start-up process, how to ensure the safety of thermal insulation, refractory, wear-resistant casting material and plastic refractory? During circulating fluidized bed boiler start-up process, in order to ensure the safety of thermal insulation, refractory, wear-resistant casting material and plastic refractory, it shall be done as follows::
1.  Strictly control the temperature changing of any point at the boiler to be less than 100 ℃ / h, in order to prevent the uneven expansion of pouring material and metal.
2. In the process of starting the fan and adjusting the air volume, strictly control the significantly changing of the boiler pressure.
3. When the coal is fed,  be sure to feed slowly and at less amount,  not to adjust the coal feeding amount significantly. (lsh)

Favourite