Home > Maintenance Area > TURBINE
After the steam turbine rotor blades fatigue fracture caused by vibration, how to judge the direction of vibration?

The blade fatigue cracks caused by vibration, in general, the distribution of crack direction perpendicular to the vibration direction of the blade. If blade fracture occurs because of vibration, the fatigue crack axial distribution. If the axial vibration broken, the fatigue crack tangential distribution.